Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nucl Med Commun ; 43(1): 1-7, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34406145

RESUMO

OBJECTIVE: Surgery is the only curative treatment for primary hyperparathyroidism. Parathyroid scintigraphy is one method used to preoperatively localize the lesion. We examined time-related changes in radiopharmaceutical uptake in parathyroid adenomas (PTAs) and thyroid gland by quantitative single-photon-emission computed tomography (SPECT) imaging to assess differences between rapid and delayed washout patterns. PATIENTS AND METHODS: The study group consisted of 35 histologically verified PTAs after radio-guided surgery extirpation in 33 patients with primary hyperparathyroidism. Patients underwent a three-phase SPECT/CT study of the neck and upper thorax post 99mTc-methoxyisobutylisonitrile (MIBI) injection. Images were reconstructed using a proprietary ordered-subset-conjugate-gradient-maximization algorithm (Siemens xSPECT Quant). PTAs were divided into those with a rapid (group A) and those with a slow (group B) washout pattern. SUVmax values of PTAs and thyroid gland tissue at 10, 90 and 180 min post 99mTc-MIBI injection were recorded and statistically assessed. Retention indexes related to the early examination were calculated for PTA and thyroid gland (RI-PTA and RI-TG). RESULTS: There were 11 PTAs in group A and 24 in group B. Significant between-group differences in PTA SUVmax and PTA/thyroid gland ratios were observed only at 180 min postinjection (P = 0.0297, P = 0.0222, respectively). RI-PTAs differed significantly at 90 and 180 min postinjection (P = 0.0298, P = 0.0431). No differences in PTA volumes, thyroid gland SUVmax values or RI-TG were observed between the groups. CONCLUSION: PTAs with rapid and slow washout patterns have different characteristics on quantitative analysis in later phases. No significant differences in directly measurable quantitative values (SUVmax, PTA/thyroid gland ratio) at the early stages of multi-phase examination were observed.


Assuntos
Neoplasias das Paratireoides
2.
Diagnostics (Basel) ; 11(4)2021 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-33918800

RESUMO

Background: Minimally invasive parathyroidectomy is the preferred treatment for primary hyperparathyroidism. Despite relatively accurate preoperative information, minimally invasive parathyroidectomy can be challenging, especially in the case of small and ectopic adenomas. Radio guidance aids in both in vivo identification and ex vivo confirmation of adenoma. In vivo accuracy is currently not satisfactory. The present study evaluated whether a beneficial effect (increased sensitivity, specificity, accuracy) is obtained with individualised timing of minimally invasive radio-guided parathyroidectomy (MIRGP) using preoperative multi-phase 99mTc-MIBI single photon emission computed tomography (SPECT)/computed tomography (CT). Methods: This randomised clinical trial was conducted from May 2016 to January 2020 in a tertiary referral hospital. Adult patients with primary hyperparathyroidism sent for 99mTc-MIBI SPECT/CT were included consecutively and randomly assigned to conventional (dual-phase) SPECT/CT and conventional MIRGP (group I) or multi-phase SPECT/CT and individualised MIRGP (group II). One hundred of 106 eligible patients were included, and 83 patients underwent complete intervention. Results: A total of 47 patients in group I and 35 patients in group II were analysed. Group II had a shorter operating time (p = 0.003). The in vivo sensitivity and accuracy of radio guidance was 85.1% in group I and 100% in group II (p = 0.046), and 90.4% in group I and 100% in group II (p = 0.021), respectively. We found no difference in the in vivo specificity and ex vivo parameters between groups. Conclusion: Individualised timing increased the in vivo sensitivity and accuracy of radio guidance and reduced operating time, as some parathyroid adenomas rapidly wash out the radionuclide.

3.
Hell J Nucl Med ; 17(3): 200-3, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25526755

RESUMO

Technological advancement in hardware and software development in myocardial perfusion imaging (MPI) leads to the shortening of acquisition time and reduction of the radiation burden to patients. We compared semiquantitative perfusion results and functional parameters of the left ventricle between new dedicated cardiac system with astigmatic collimators called IQ-SPECT (Siemens Medical Solutions, USA) and conventional single photon emission tomography (SPET) system equipped with standard low energy high resolution collimators. A group of randomly selected 81 patients underwent consecutively the MPI procedure on IQ-SPECT and on conventional SPET systen, both without attenuation correction. The summed scores and the values of the functional parameters of the left ventricle: ejection fraction (EF), end-systolic and end-diastolic volumes (ESV, EDV) received from the automatic analysis software were compared and statistically analyzed. Our results showed that summed scores values were significantly higher for the IQ-SPECT system in comparison to the conventional one. Calculated EF were significantly lower for IQ-SPECT, whereas evaluated left ventricular volumes (LVV) were significantly higher for this system. In conclusion, we recorded significant differences in automatically calculated semiquantitative perfusion and functional parameters when compared uncorrected studies obtained by the IQ-SPECT with the conventional SPET system.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Aumento da Imagem/métodos , Imagem de Perfusão do Miocárdio/métodos , Volume Sistólico , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Doença da Artéria Coronariana/complicações , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/etiologia
4.
Prog Transplant ; 24(2): 199-205, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24919738

RESUMO

The well-described disparity between the need for and the supply of organs suitable for transplant is growing. Because of this disparity, mortality of patients listed for transplant is increasing. Donors who die of intoxication (including victims of methanol poisoning) represent less than 1% of suitable donors and might be used to increase the supply of organs. They are often not accepted as donors by transplant specialists, because of concerns about patients' outcomes with these grafts. Three cases of fatal methanol intoxication that resulted in transplants of 6 kidneys are evaluated.


Assuntos
Morte Encefálica , Seleção do Doador , Falência Renal Crônica/cirurgia , Transplante de Rim , Metanol/intoxicação , Solventes/intoxicação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...